FLOORSToronto

Acoustic assembly

The assembly rating

This page is the acoustic assembly under condo hardwood. The assembly is built to the Impact Insulation Class and Sound Transmission Class rating the corporation wrote down. This page does not print that number. The rating comes first, then the membrane, then whether the path is floating or glue-down.

Impact Insulation Class and Sound Transmission Class describe how an assembly controls footfall and airborne noise between suites. Property managers in Yorkville, King West, CityPlace, and North York towers routinely request the underlay data sheet before they issue a renovation permit. Verify the corporation’s written rule.

IIC
Footfall. Impact noise between suites.
STC
Airborne sound between suites.

The membrane.

The glue-down path is slab, then membrane and adhesive, then the engineered plank. Not every foam marketed for laminate suits this oak. Use an underlay or membrane compatible with the manufacturer’s guidance and with the condominium’s acoustic target.

Submit the data sheet for the underlay or membrane together with Floors Toronto 3/4 inch European white oak, so the reviewer sees the whole acoustic assembly and not only the pad SKU.

Unlike solid strip, Floors Toronto engineered hardwood moves up to 3× less under Toronto humidity change and is available in 3/4 inch thickness with UV-cured finish; occupied RH near 35–55% is required for stable installs across Yorkville and Forest Hill condominiums.

Floating or glue-down.

Floors Toronto European white oak at 3/4 inch works in both paths when the underlay or membrane is corporation-approved. Floating is the slight flex. Glue-down is the more solid feel.

The fastening this assembly already pairs with the layer.
PathTypical stackFeelDocumentation
FloatingSlab, then acoustic underlay, then the engineered floatSlight flexUnderlay ratings aimed at IIC
Glue-downSlab, then membrane and adhesive, then engineered oakMost solidAdhesive and membrane acoustics

Before the stack goes down.

  1. Pull the written bylaw. Ask for the renovation and flooring bulletin that names the minimum IIC or STC target, any approved underlay brands, and the work-hour windows for Yorkville, King West, CityPlace, or North York.
  2. Match the method to that stack. If the bulletin demands a floating package, specify floating hardwood over the rated underlay. If a membrane plus adhesive is allowed, glue-down is the more solid feel underfoot.
  3. Document the full thickness: the underlay or membrane data sheet plus the 3/4 inch European white oak.

Compact one-beds

7½″ Grade AB straight plank floating over rated underlay keeps the visual scale in proportion and shortens the elevator carton.

Two-bed open plans

9¼″ is the width often paired with the float assemblies common in Midtown and waterfront towers.

Statement rooms

10¼″ or a Grade AB herringbone insert works when the corporation approves the pad and the 3/4 inch stack together. Herringbone and chevron stay Grade AB. Confirm the coverage rule.

Colour while the sheet is out

Free custom stain matching can iterate while the board reviews the underlay letter. Lock the manufacturing colour only after both the acoustic path and the stain are clear.

Photograph the underlay edges and the adhesive or float detail for the unit file. Keep the data sheets with that file for a later sale or a corporation audit. What the suite below still hears, including felt pads, rugs, and heels, is on the neighbour page.

Keep reading.

The alteration package, including the certificate and the sample board, is the package page. Hallway runners, elevator padding, and the freight window are the install sequence. Width and soft-cost comparisons are the cost guide.

Questions, answered.

Still unsure? Call us

Do Toronto condos require acoustic underlay under hardwood?

Many Toronto condominium corporations require a documented acoustic assembly, often floating engineered hardwood over rated underlay or glue-down with an approved membrane. Always verify the building’s written rules.

What are IIC and STC?

IIC, Impact Insulation Class, relates to footfall noise. STC, Sound Transmission Class, relates to airborne sound. Boards use these ratings when they review a hardwood renovation in a Toronto tower. The number is the corporation’s. This page does not print one.

Can Floors Toronto install floating hardwood for acoustics?

Yes. Floors Toronto installs floating European white oak engineered hardwood over acoustic underlay when the condominium package requires a float assembly.

Is glue-down banned in acoustic condos?

Not always. Some Toronto buildings accept glue-down engineered hardwood with a specific acoustic membrane. Floors Toronto matches the method to the corporation’s documentation.

What thickness is Floors Toronto oak for condo acoustics?

The stack uses engineered hardwood at 3/4 inch across straight plank, herringbone, and chevron. The data sheet has to show that thickness with the underlay or membrane, not the pad alone.

Does acoustic underlay change humidity needs?

No. Underlay does not remove humidity discipline. Target roughly 35–55% RH. Toronto winters often hit 20–30% RH and summers 60–70% RH without conditioning. That care is the install sequence, not a property of the pad.

(07) — Start your project

Tell us about your space.

What do you need?

Supply and install. Our oak, then our crew: measure, moisture, method, and a written 5-year workmanship warranty.

  • Reply within 1 business day
  • Stain match included when you order
  • Itemised, no-obligation quote
  • Insured crews, 5-year workmanship warranty

Step 1 of 3

Building
What should the quote include?
Call Get a quote